This has not been tested in the gate for a long time and was only added to enable CI in the early days of OpenStack. Time to bid adieu. Change-Id: I7a157f37d2a67e1174a1725fd579c761d81a09b1 Signed-off-by: Stephen Finucane <stephenfin@redhat.com>
1481 lines
53 KiB
Python
1481 lines
53 KiB
Python
# needs:fix_opt_description
|
|
# needs:check_deprecation_status
|
|
# needs:check_opt_group_and_type
|
|
# needs:fix_opt_description_indentation
|
|
# needs:fix_opt_registration_consistency
|
|
|
|
# Copyright 2016 OpenStack Foundation
|
|
# All Rights Reserved.
|
|
#
|
|
# Licensed under the Apache License, Version 2.0 (the "License"); you may
|
|
# not use this file except in compliance with the License. You may obtain
|
|
# a copy of the License at
|
|
#
|
|
# http://www.apache.org/licenses/LICENSE-2.0
|
|
#
|
|
# Unless required by applicable law or agreed to in writing, software
|
|
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
|
|
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
|
|
# License for the specific language governing permissions and limitations
|
|
# under the License.
|
|
|
|
import itertools
|
|
|
|
from oslo_config import cfg
|
|
|
|
from oslo_config import types
|
|
|
|
from nova.conf import paths
|
|
|
|
|
|
libvirt_group = cfg.OptGroup("libvirt",
|
|
title="Libvirt Options",
|
|
help="""
|
|
Libvirt options allows cloud administrator to configure related
|
|
libvirt hypervisor driver to be used within an OpenStack deployment.
|
|
|
|
Almost all of the libvirt config options are influence by ``virt_type`` config
|
|
which describes the virtualization type (or so called domain type) libvirt
|
|
should use for specific features such as live migration, snapshot.
|
|
""")
|
|
|
|
libvirt_general_opts = [
|
|
cfg.StrOpt('rescue_image_id',
|
|
help="""
|
|
The ID of the image to boot from to rescue data from a corrupted instance.
|
|
|
|
If the rescue REST API operation doesn't provide an ID of an image to
|
|
use, the image which is referenced by this ID is used. If this
|
|
option is not set, the image from the instance is used.
|
|
|
|
Possible values:
|
|
|
|
* An ID of an image or nothing. If it points to an *Amazon Machine
|
|
Image* (AMI), consider to set the config options ``rescue_kernel_id``
|
|
and ``rescue_ramdisk_id`` too. If nothing is set, the image of the instance
|
|
is used.
|
|
|
|
Related options:
|
|
|
|
* ``rescue_kernel_id``: If the chosen rescue image allows the separate
|
|
definition of its kernel disk, the value of this option is used,
|
|
if specified. This is the case when *Amazon*'s AMI/AKI/ARI image
|
|
format is used for the rescue image.
|
|
* ``rescue_ramdisk_id``: If the chosen rescue image allows the separate
|
|
definition of its RAM disk, the value of this option is used if,
|
|
specified. This is the case when *Amazon*'s AMI/AKI/ARI image
|
|
format is used for the rescue image.
|
|
"""),
|
|
cfg.StrOpt('rescue_kernel_id',
|
|
help="""
|
|
The ID of the kernel (AKI) image to use with the rescue image.
|
|
|
|
If the chosen rescue image allows the separate definition of its kernel
|
|
disk, the value of this option is used, if specified. This is the case
|
|
when *Amazon*'s AMI/AKI/ARI image format is used for the rescue image.
|
|
|
|
Possible values:
|
|
|
|
* An ID of an kernel image or nothing. If nothing is specified, the kernel
|
|
disk from the instance is used if it was launched with one.
|
|
|
|
Related options:
|
|
|
|
* ``rescue_image_id``: If that option points to an image in *Amazon*'s
|
|
AMI/AKI/ARI image format, it's useful to use ``rescue_kernel_id`` too.
|
|
"""),
|
|
cfg.StrOpt('rescue_ramdisk_id',
|
|
help="""
|
|
The ID of the RAM disk (ARI) image to use with the rescue image.
|
|
|
|
If the chosen rescue image allows the separate definition of its RAM
|
|
disk, the value of this option is used, if specified. This is the case
|
|
when *Amazon*'s AMI/AKI/ARI image format is used for the rescue image.
|
|
|
|
Possible values:
|
|
|
|
* An ID of a RAM disk image or nothing. If nothing is specified, the RAM
|
|
disk from the instance is used if it was launched with one.
|
|
|
|
Related options:
|
|
|
|
* ``rescue_image_id``: If that option points to an image in *Amazon*'s
|
|
AMI/AKI/ARI image format, it's useful to use ``rescue_ramdisk_id`` too.
|
|
"""),
|
|
cfg.StrOpt('virt_type',
|
|
default='kvm',
|
|
choices=('kvm', 'lxc', 'qemu', 'xen', 'parallels'),
|
|
help="""
|
|
Describes the virtualization type (or so called domain type) libvirt should
|
|
use.
|
|
|
|
The choice of this type must match the underlying virtualization strategy
|
|
you have chosen for this host.
|
|
|
|
Related options:
|
|
|
|
* ``connection_uri``: depends on this
|
|
* ``disk_prefix``: depends on this
|
|
* ``cpu_mode``: depends on this
|
|
* ``cpu_models``: depends on this
|
|
"""),
|
|
cfg.StrOpt('connection_uri',
|
|
default='',
|
|
help="""
|
|
Overrides the default libvirt URI of the chosen virtualization type.
|
|
|
|
If set, Nova will use this URI to connect to libvirt.
|
|
|
|
Possible values:
|
|
|
|
* An URI like ``qemu:///system`` or ``xen+ssh://oirase/`` for example.
|
|
This is only necessary if the URI differs to the commonly known URIs
|
|
for the chosen virtualization type.
|
|
|
|
Related options:
|
|
|
|
* ``virt_type``: Influences what is used as default value here.
|
|
"""),
|
|
cfg.BoolOpt('inject_password',
|
|
default=False,
|
|
help="""
|
|
Allow the injection of an admin password for instance only at ``create`` and
|
|
``rebuild`` process.
|
|
|
|
There is no agent needed within the image to do this. If *libguestfs* is
|
|
available on the host, it will be used. Otherwise *nbd* is used. The file
|
|
system of the image will be mounted and the admin password, which is provided
|
|
in the REST API call will be injected as password for the root user. If no
|
|
root user is available, the instance won't be launched and an error is thrown.
|
|
Be aware that the injection is *not* possible when the instance gets launched
|
|
from a volume.
|
|
|
|
*Linux* distribution guest only.
|
|
|
|
Possible values:
|
|
|
|
* True: Allows the injection.
|
|
* False: Disallows the injection. Any via the REST API provided admin password
|
|
will be silently ignored.
|
|
|
|
Related options:
|
|
|
|
* ``inject_partition``: That option will decide about the discovery and usage
|
|
of the file system. It also can disable the injection at all.
|
|
"""),
|
|
cfg.BoolOpt('inject_key',
|
|
default=False,
|
|
help="""
|
|
Allow the injection of an SSH key at boot time.
|
|
|
|
There is no agent needed within the image to do this. If *libguestfs* is
|
|
available on the host, it will be used. Otherwise *nbd* is used. The file
|
|
system of the image will be mounted and the SSH key, which is provided
|
|
in the REST API call will be injected as SSH key for the root user and
|
|
appended to the ``authorized_keys`` of that user. The SELinux context will
|
|
be set if necessary. Be aware that the injection is *not* possible when the
|
|
instance gets launched from a volume.
|
|
|
|
This config option will enable directly modifying the instance disk and does
|
|
not affect what cloud-init may do using data from config_drive option or the
|
|
metadata service.
|
|
|
|
*Linux* distribution guest only.
|
|
|
|
Related options:
|
|
|
|
* ``inject_partition``: That option will decide about the discovery and usage
|
|
of the file system. It also can disable the injection at all.
|
|
"""),
|
|
cfg.IntOpt('inject_partition',
|
|
default=-2,
|
|
min=-2,
|
|
help="""
|
|
Determines the way how the file system is chosen to inject data into it.
|
|
|
|
*libguestfs* will be used a first solution to inject data. If that's not
|
|
available on the host, the image will be locally mounted on the host as a
|
|
fallback solution. If libguestfs is not able to determine the root partition
|
|
(because there are more or less than one root partition) or cannot mount the
|
|
file system it will result in an error and the instance won't be boot.
|
|
|
|
Possible values:
|
|
|
|
* -2 => disable the injection of data.
|
|
* -1 => find the root partition with the file system to mount with libguestfs
|
|
* 0 => The image is not partitioned
|
|
* >0 => The number of the partition to use for the injection
|
|
|
|
*Linux* distribution guest only.
|
|
|
|
Related options:
|
|
|
|
* ``inject_key``: If this option allows the injection of a SSH key it depends
|
|
on value greater or equal to -1 for ``inject_partition``.
|
|
* ``inject_password``: If this option allows the injection of an admin password
|
|
it depends on value greater or equal to -1 for ``inject_partition``.
|
|
* ``guestfs`` You can enable the debug log level of libguestfs with this
|
|
config option. A more verbose output will help in debugging issues.
|
|
* ``virt_type``: If you use ``lxc`` as virt_type it will be treated as a
|
|
single partition image
|
|
"""),
|
|
cfg.StrOpt('live_migration_scheme',
|
|
help="""
|
|
URI scheme used for live migration.
|
|
|
|
Override the default libvirt live migration scheme (which is dependent on
|
|
virt_type). If this option is set to None, nova will automatically choose a
|
|
sensible default based on the hypervisor. It is not recommended that you change
|
|
this unless you are very sure that hypervisor supports a particular scheme.
|
|
|
|
Related options:
|
|
|
|
* ``virt_type``: This option is meaningful only when ``virt_type`` is set to
|
|
`kvm` or `qemu`.
|
|
* ``live_migration_uri``: If ``live_migration_uri`` value is not None, the
|
|
scheme used for live migration is taken from ``live_migration_uri`` instead.
|
|
"""),
|
|
cfg.HostAddressOpt('live_migration_inbound_addr',
|
|
help="""
|
|
Target used for live migration traffic.
|
|
|
|
If this option is set to None, the hostname of the migration target compute
|
|
node will be used.
|
|
|
|
This option is useful in environments where the live-migration traffic can
|
|
impact the network plane significantly. A separate network for live-migration
|
|
traffic can then use this config option and avoids the impact on the
|
|
management network.
|
|
|
|
Related options:
|
|
|
|
* ``live_migration_tunnelled``: The live_migration_inbound_addr value is
|
|
ignored if tunneling is enabled.
|
|
"""),
|
|
cfg.StrOpt('live_migration_uri',
|
|
deprecated_for_removal=True,
|
|
deprecated_since="15.0.0",
|
|
deprecated_reason="""
|
|
live_migration_uri is deprecated for removal in favor of two other options that
|
|
allow to change live migration scheme and target URI: ``live_migration_scheme``
|
|
and ``live_migration_inbound_addr`` respectively.
|
|
""",
|
|
help="""
|
|
Live migration target URI to use.
|
|
|
|
Override the default libvirt live migration target URI (which is dependent
|
|
on virt_type). Any included "%s" is replaced with the migration target
|
|
hostname.
|
|
|
|
If this option is set to None (which is the default), Nova will automatically
|
|
generate the `live_migration_uri` value based on only 4 supported `virt_type`
|
|
in following list:
|
|
|
|
* 'kvm': 'qemu+tcp://%s/system'
|
|
* 'qemu': 'qemu+tcp://%s/system'
|
|
* 'xen': 'xenmigr://%s/system'
|
|
* 'parallels': 'parallels+tcp://%s/system'
|
|
|
|
Related options:
|
|
|
|
* ``live_migration_inbound_addr``: If ``live_migration_inbound_addr`` value
|
|
is not None and ``live_migration_tunnelled`` is False, the ip/hostname
|
|
address of target compute node is used instead of ``live_migration_uri`` as
|
|
the uri for live migration.
|
|
* ``live_migration_scheme``: If ``live_migration_uri`` is not set, the scheme
|
|
used for live migration is taken from ``live_migration_scheme`` instead.
|
|
"""),
|
|
cfg.BoolOpt('live_migration_tunnelled',
|
|
default=False,
|
|
help="""
|
|
Enable tunnelled migration.
|
|
|
|
This option enables the tunnelled migration feature, where migration data is
|
|
transported over the libvirtd connection. If enabled, we use the
|
|
VIR_MIGRATE_TUNNELLED migration flag, avoiding the need to configure
|
|
the network to allow direct hypervisor to hypervisor communication.
|
|
If False, use the native transport. If not set, Nova will choose a
|
|
sensible default based on, for example the availability of native
|
|
encryption support in the hypervisor. Enabling this option will definitely
|
|
impact performance massively.
|
|
|
|
Note that this option is NOT compatible with use of block migration.
|
|
|
|
Related options:
|
|
|
|
* ``live_migration_inbound_addr``: The live_migration_inbound_addr value is
|
|
ignored if tunneling is enabled.
|
|
"""),
|
|
cfg.IntOpt('live_migration_bandwidth',
|
|
default=0,
|
|
help="""
|
|
Maximum bandwidth(in MiB/s) to be used during migration.
|
|
|
|
If set to 0, the hypervisor will choose a suitable default. Some hypervisors
|
|
do not support this feature and will return an error if bandwidth is not 0.
|
|
Please refer to the libvirt documentation for further details.
|
|
"""),
|
|
cfg.IntOpt('live_migration_downtime',
|
|
default=500,
|
|
min=100,
|
|
help="""
|
|
Maximum permitted downtime, in milliseconds, for live migration
|
|
switchover.
|
|
|
|
Will be rounded up to a minimum of 100ms. You can increase this value
|
|
if you want to allow live-migrations to complete faster, or avoid
|
|
live-migration timeout errors by allowing the guest to be paused for
|
|
longer during the live-migration switch over.
|
|
|
|
Related options:
|
|
|
|
* live_migration_completion_timeout
|
|
"""),
|
|
cfg.IntOpt('live_migration_downtime_steps',
|
|
default=10,
|
|
min=3,
|
|
help="""
|
|
Number of incremental steps to reach max downtime value.
|
|
|
|
Will be rounded up to a minimum of 3 steps.
|
|
"""),
|
|
cfg.IntOpt('live_migration_downtime_delay',
|
|
default=75,
|
|
min=3,
|
|
help="""
|
|
Time to wait, in seconds, between each step increase of the migration
|
|
downtime.
|
|
|
|
Minimum delay is 3 seconds. Value is per GiB of guest RAM + disk to be
|
|
transferred, with lower bound of a minimum of 2 GiB per device.
|
|
"""),
|
|
cfg.IntOpt('live_migration_completion_timeout',
|
|
default=800,
|
|
min=0,
|
|
mutable=True,
|
|
help="""
|
|
Time to wait, in seconds, for migration to successfully complete transferring
|
|
data before aborting the operation.
|
|
|
|
Value is per GiB of guest RAM + disk to be transferred, with lower bound of
|
|
a minimum of 2 GiB. Should usually be larger than downtime delay * downtime
|
|
steps. Set to 0 to disable timeouts.
|
|
|
|
Related options:
|
|
|
|
* live_migration_downtime
|
|
* live_migration_downtime_steps
|
|
* live_migration_downtime_delay
|
|
"""),
|
|
cfg.StrOpt('live_migration_timeout_action',
|
|
default='abort',
|
|
choices=('abort', 'force_complete'),
|
|
mutable=True,
|
|
help="""
|
|
This option will be used to determine what action will be taken against a
|
|
VM after ``live_migration_completion_timeout`` expires. By default, the live
|
|
migrate operation will be aborted after completion timeout. If it is set to
|
|
``force_complete``, the compute service will either pause the VM or trigger
|
|
post-copy depending on if post copy is enabled and available
|
|
(``live_migration_permit_post_copy`` is set to True).
|
|
|
|
Related options:
|
|
|
|
* live_migration_completion_timeout
|
|
* live_migration_permit_post_copy
|
|
"""),
|
|
cfg.BoolOpt('live_migration_permit_post_copy',
|
|
default=False,
|
|
help="""
|
|
This option allows nova to switch an on-going live migration to post-copy
|
|
mode, i.e., switch the active VM to the one on the destination node before the
|
|
migration is complete, therefore ensuring an upper bound on the memory that
|
|
needs to be transferred. Post-copy requires libvirt>=1.3.3 and QEMU>=2.5.0.
|
|
|
|
When permitted, post-copy mode will be automatically activated if
|
|
we reach the timeout defined by ``live_migration_completion_timeout`` and
|
|
``live_migration_timeout_action`` is set to 'force_complete'. Note if you
|
|
change to no timeout or choose to use 'abort',
|
|
i.e. ``live_migration_completion_timeout = 0``, then there will be no
|
|
automatic switch to post-copy.
|
|
|
|
The live-migration force complete API also uses post-copy when permitted. If
|
|
post-copy mode is not available, force complete falls back to pausing the VM
|
|
to ensure the live-migration operation will complete.
|
|
|
|
When using post-copy mode, if the source and destination hosts lose network
|
|
connectivity, the VM being live-migrated will need to be rebooted. For more
|
|
details, please see the Administration guide.
|
|
|
|
Related options:
|
|
|
|
* live_migration_permit_auto_converge
|
|
* live_migration_timeout_action
|
|
"""),
|
|
cfg.BoolOpt('live_migration_permit_auto_converge',
|
|
default=False,
|
|
help="""
|
|
This option allows nova to start live migration with auto converge on.
|
|
|
|
Auto converge throttles down CPU if a progress of on-going live migration
|
|
is slow. Auto converge will only be used if this flag is set to True and
|
|
post copy is not permitted or post copy is unavailable due to the version
|
|
of libvirt and QEMU in use.
|
|
|
|
Related options:
|
|
|
|
* live_migration_permit_post_copy
|
|
"""),
|
|
cfg.StrOpt('snapshot_image_format',
|
|
choices=[
|
|
('raw', 'RAW disk format'),
|
|
('qcow2', 'KVM default disk format'),
|
|
('vmdk', 'VMWare default disk format'),
|
|
('vdi', 'VirtualBox default disk format'),
|
|
],
|
|
help="""
|
|
Determine the snapshot image format when sending to the image service.
|
|
|
|
If set, this decides what format is used when sending the snapshot to the
|
|
image service. If not set, defaults to same type as source image.
|
|
"""),
|
|
cfg.BoolOpt('live_migration_with_native_tls',
|
|
default=False,
|
|
help="""
|
|
Use QEMU-native TLS encryption when live migrating.
|
|
|
|
This option will allow both migration stream (guest RAM plus device
|
|
state) *and* disk stream to be transported over native TLS, i.e. TLS
|
|
support built into QEMU.
|
|
|
|
Prerequisite: TLS environment is configured correctly on all relevant
|
|
Compute nodes. This means, Certificate Authority (CA), server, client
|
|
certificates, their corresponding keys, and their file permisssions are
|
|
in place, and are validated.
|
|
|
|
Notes:
|
|
|
|
* To have encryption for migration stream and disk stream (also called:
|
|
"block migration"), ``live_migration_with_native_tls`` is the
|
|
preferred config attribute instead of ``live_migration_tunnelled``.
|
|
|
|
* The ``live_migration_tunnelled`` will be deprecated in the long-term
|
|
for two main reasons: (a) it incurs a huge performance penalty; and
|
|
(b) it is not compatible with block migration. Therefore, if your
|
|
compute nodes have at least libvirt 4.4.0 and QEMU 2.11.0, it is
|
|
strongly recommended to use ``live_migration_with_native_tls``.
|
|
|
|
* The ``live_migration_tunnelled`` and
|
|
``live_migration_with_native_tls`` should not be used at the same
|
|
time.
|
|
|
|
* Unlike ``live_migration_tunnelled``, the
|
|
``live_migration_with_native_tls`` *is* compatible with block
|
|
migration. That is, with this option, NBD stream, over which disks
|
|
are migrated to a target host, will be encrypted.
|
|
|
|
Related options:
|
|
|
|
``live_migration_tunnelled``: This transports migration stream (but not
|
|
disk stream) over libvirtd.
|
|
|
|
"""),
|
|
cfg.StrOpt('disk_prefix',
|
|
help="""
|
|
Override the default disk prefix for the devices attached to an instance.
|
|
|
|
If set, this is used to identify a free disk device name for a bus.
|
|
|
|
Possible values:
|
|
|
|
* Any prefix which will result in a valid disk device name like 'sda' or 'hda'
|
|
for example. This is only necessary if the device names differ to the
|
|
commonly known device name prefixes for a virtualization type such as: sd,
|
|
xvd, uvd, vd.
|
|
|
|
Related options:
|
|
|
|
* ``virt_type``: Influences which device type is used, which determines
|
|
the default disk prefix.
|
|
"""),
|
|
cfg.IntOpt('wait_soft_reboot_seconds',
|
|
default=120,
|
|
help='Number of seconds to wait for instance to shut down after'
|
|
' soft reboot request is made. We fall back to hard reboot'
|
|
' if instance does not shutdown within this window.'),
|
|
cfg.StrOpt('cpu_mode',
|
|
choices=[
|
|
('host-model', 'Clone the host CPU feature flags'),
|
|
('host-passthrough', 'Use the host CPU model exactly'),
|
|
('custom', 'Use the CPU model in ``[libvirt]cpu_models``'),
|
|
('none', "Don't set a specific CPU model. For instances with "
|
|
"``[libvirt] virt_type`` as KVM/QEMU, the default CPU model from "
|
|
"QEMU will be used, which provides a basic set of CPU features "
|
|
"that are compatible with most hosts"),
|
|
],
|
|
help="""
|
|
Is used to set the CPU mode an instance should have.
|
|
|
|
If ``virt_type="kvm|qemu"``, it will default to ``host-model``, otherwise it
|
|
will default to ``none``.
|
|
|
|
Related options:
|
|
|
|
* ``cpu_models``: This should be set ONLY when ``cpu_mode`` is set to
|
|
``custom``. Otherwise, it would result in an error and the instance launch
|
|
will fail.
|
|
"""),
|
|
cfg.ListOpt('cpu_models',
|
|
deprecated_name='cpu_model',
|
|
default=[],
|
|
help="""
|
|
An ordered list of CPU models the host supports.
|
|
|
|
It is expected that the list is ordered so that the more common and less
|
|
advanced CPU models are listed earlier. Here is an example:
|
|
``SandyBridge,IvyBridge,Haswell,Broadwell``, the latter CPU model's features is
|
|
richer that the previous CPU model.
|
|
|
|
Possible values:
|
|
|
|
* The named CPU models listed in ``/usr/share/libvirt/cpu_map.xml`` for
|
|
libvirt prior to version 4.7.0 or ``/usr/share/libvirt/cpu_map/*.xml``
|
|
for version 4.7.0 and higher.
|
|
|
|
Related options:
|
|
|
|
* ``cpu_mode``: This should be set to ``custom`` ONLY when you want to
|
|
configure (via ``cpu_models``) a specific named CPU model. Otherwise, it
|
|
would result in an error and the instance launch will fail.
|
|
* ``virt_type``: Only the virtualization types ``kvm`` and ``qemu`` use this.
|
|
|
|
.. note::
|
|
Be careful to only specify models which can be fully supported in
|
|
hardware.
|
|
"""),
|
|
cfg.ListOpt(
|
|
'cpu_model_extra_flags',
|
|
item_type=types.String(
|
|
ignore_case=True,
|
|
),
|
|
default=[],
|
|
help="""
|
|
This allows specifying granular CPU feature flags when configuring CPU
|
|
models. For example, to explicitly specify the ``pcid``
|
|
(Process-Context ID, an Intel processor feature -- which is now required
|
|
to address the guest performance degradation as a result of applying the
|
|
"Meltdown" CVE fixes to certain Intel CPU models) flag to the
|
|
"IvyBridge" virtual CPU model::
|
|
|
|
[libvirt]
|
|
cpu_mode = custom
|
|
cpu_models = IvyBridge
|
|
cpu_model_extra_flags = pcid
|
|
|
|
To specify multiple CPU flags (e.g. the Intel ``VMX`` to expose the
|
|
virtualization extensions to the guest, or ``pdpe1gb`` to configure 1GB
|
|
huge pages for CPU models that do not provide it)::
|
|
|
|
[libvirt]
|
|
cpu_mode = custom
|
|
cpu_models = Haswell-noTSX-IBRS
|
|
cpu_model_extra_flags = PCID, VMX, pdpe1gb
|
|
|
|
As it can be noticed from above, the ``cpu_model_extra_flags`` config
|
|
attribute is case insensitive. And specifying extra flags is valid in
|
|
combination with all the three possible values for ``cpu_mode``:
|
|
``custom`` (this also requires an explicit ``cpu_models`` to be
|
|
specified), ``host-model``, or ``host-passthrough``. A valid example
|
|
for allowing extra CPU flags even for ``host-passthrough`` mode is that
|
|
sometimes QEMU may disable certain CPU features -- e.g. Intel's
|
|
"invtsc", Invariable Time Stamp Counter, CPU flag. And if you need to
|
|
expose that CPU flag to the Nova instance, the you need to explicitly
|
|
ask for it.
|
|
|
|
The possible values for ``cpu_model_extra_flags`` depends on the CPU
|
|
model in use. Refer to ``/usr/share/libvirt/cpu_map.xml`` for libvirt
|
|
prior to version 4.7.0 or ``/usr/share/libvirt/cpu_map/*.xml`` thereafter
|
|
for possible CPU feature flags for a given CPU model.
|
|
|
|
Note that when using this config attribute to set the 'PCID' CPU flag
|
|
with the ``custom`` CPU mode, not all virtual (i.e. libvirt / QEMU) CPU
|
|
models need it:
|
|
|
|
* The only virtual CPU models that include the 'PCID' capability are
|
|
Intel "Haswell", "Broadwell", and "Skylake" variants.
|
|
|
|
* The libvirt / QEMU CPU models "Nehalem", "Westmere", "SandyBridge",
|
|
and "IvyBridge" will _not_ expose the 'PCID' capability by default,
|
|
even if the host CPUs by the same name include it. I.e. 'PCID' needs
|
|
to be explicitly specified when using the said virtual CPU models.
|
|
|
|
The libvirt driver's default CPU mode, ``host-model``, will do the right
|
|
thing with respect to handling 'PCID' CPU flag for the guest --
|
|
*assuming* you are running updated processor microcode, host and guest
|
|
kernel, libvirt, and QEMU. The other mode, ``host-passthrough``, checks
|
|
if 'PCID' is available in the hardware, and if so directly passes it
|
|
through to the Nova guests. Thus, in context of 'PCID', with either of
|
|
these CPU modes (``host-model`` or ``host-passthrough``), there is no
|
|
need to use the ``cpu_model_extra_flags``.
|
|
|
|
Related options:
|
|
|
|
* cpu_mode
|
|
* cpu_models
|
|
"""),
|
|
cfg.StrOpt('snapshots_directory',
|
|
default='$instances_path/snapshots',
|
|
help='Location where libvirt driver will store snapshots '
|
|
'before uploading them to image service'),
|
|
cfg.StrOpt('xen_hvmloader_path',
|
|
default='/usr/lib/xen/boot/hvmloader',
|
|
help='Location where the Xen hvmloader is kept'),
|
|
cfg.ListOpt('disk_cachemodes',
|
|
default=[],
|
|
help="""
|
|
Specific cache modes to use for different disk types.
|
|
|
|
For example: file=directsync,block=none,network=writeback
|
|
|
|
For local or direct-attached storage, it is recommended that you use
|
|
writethrough (default) mode, as it ensures data integrity and has acceptable
|
|
I/O performance for applications running in the guest, especially for read
|
|
operations. However, caching mode none is recommended for remote NFS storage,
|
|
because direct I/O operations (O_DIRECT) perform better than synchronous I/O
|
|
operations (with O_SYNC). Caching mode none effectively turns all guest I/O
|
|
operations into direct I/O operations on the host, which is the NFS client in
|
|
this environment.
|
|
|
|
Possible cache modes:
|
|
|
|
* default: "It Depends" -- For Nova-managed disks, ``none``, if the host
|
|
file system is capable of Linux's 'O_DIRECT' semantics; otherwise
|
|
``writeback``. For volume drivers, the default is driver-dependent:
|
|
``none`` for everything except for SMBFS and Virtuzzo (which use
|
|
``writeback``).
|
|
* none: With caching mode set to none, the host page cache is disabled, but
|
|
the disk write cache is enabled for the guest. In this mode, the write
|
|
performance in the guest is optimal because write operations bypass the host
|
|
page cache and go directly to the disk write cache. If the disk write cache
|
|
is battery-backed, or if the applications or storage stack in the guest
|
|
transfer data properly (either through fsync operations or file system
|
|
barriers), then data integrity can be ensured. However, because the host
|
|
page cache is disabled, the read performance in the guest would not be as
|
|
good as in the modes where the host page cache is enabled, such as
|
|
writethrough mode. Shareable disk devices, like for a multi-attachable block
|
|
storage volume, will have their cache mode set to 'none' regardless of
|
|
configuration.
|
|
* writethrough: With caching set to writethrough mode, the host page cache is
|
|
enabled, but the disk write cache is disabled for the guest. Consequently,
|
|
this caching mode ensures data integrity even if the applications and storage
|
|
stack in the guest do not transfer data to permanent storage properly (either
|
|
through fsync operations or file system barriers). Because the host page
|
|
cache is enabled in this mode, the read performance for applications running
|
|
in the guest is generally better. However, the write performance might be
|
|
reduced because the disk write cache is disabled.
|
|
* writeback: With caching set to writeback mode, both the host page
|
|
cache and the disk write cache are enabled for the guest. Because of
|
|
this, the I/O performance for applications running in the guest is
|
|
good, but the data is not protected in a power failure. As a result,
|
|
this caching mode is recommended only for temporary data where
|
|
potential data loss is not a concern.
|
|
NOTE: Certain backend disk mechanisms may provide safe
|
|
writeback cache semantics. Specifically those that bypass the host
|
|
page cache, such as QEMU's integrated RBD driver. Ceph documentation
|
|
recommends setting this to writeback for maximum performance while
|
|
maintaining data safety.
|
|
* directsync: Like "writethrough", but it bypasses the host page cache.
|
|
* unsafe: Caching mode of unsafe ignores cache transfer operations
|
|
completely. As its name implies, this caching mode should be used only for
|
|
temporary data where data loss is not a concern. This mode can be useful for
|
|
speeding up guest installations, but you should switch to another caching
|
|
mode in production environments.
|
|
"""),
|
|
cfg.StrOpt('rng_dev_path',
|
|
default='/dev/urandom',
|
|
help="""
|
|
The path to an RNG (Random Number Generator) device that will be used as
|
|
the source of entropy on the host. Since libvirt 1.3.4, any path (that
|
|
returns random numbers when read) is accepted. The recommended source
|
|
of entropy is ``/dev/urandom`` -- it is non-blocking, therefore
|
|
relatively fast; and avoids the limitations of ``/dev/random``, which is
|
|
a legacy interface. For more details (and comparision between different
|
|
RNG sources), refer to the "Usage" section in the Linux kernel API
|
|
documentation for ``[u]random``:
|
|
http://man7.org/linux/man-pages/man4/urandom.4.html and
|
|
http://man7.org/linux/man-pages/man7/random.7.html.
|
|
"""),
|
|
cfg.ListOpt('hw_machine_type',
|
|
help='For qemu or KVM guests, set this option to specify '
|
|
'a default machine type per host architecture. '
|
|
'You can find a list of supported machine types '
|
|
'in your environment by checking the output of the '
|
|
':command:`virsh capabilities` command. The format of '
|
|
'the value for this config option is '
|
|
'``host-arch=machine-type``. For example: '
|
|
'``x86_64=machinetype1,armv7l=machinetype2``.'),
|
|
cfg.StrOpt('sysinfo_serial',
|
|
default='unique',
|
|
choices=(
|
|
('none', 'A serial number entry is not added to the guest '
|
|
'domain xml.'),
|
|
('os', 'A UUID serial number is generated from the host '
|
|
'``/etc/machine-id`` file.'),
|
|
('hardware', 'A UUID for the host hardware as reported by '
|
|
'libvirt. This is typically from the host '
|
|
'SMBIOS data, unless it has been overridden '
|
|
'in ``libvirtd.conf``.'),
|
|
('auto', 'Uses the "os" source if possible, else '
|
|
'"hardware".'),
|
|
('unique', 'Uses instance UUID as the serial number.'),
|
|
),
|
|
help="""
|
|
The data source used to the populate the host "serial" UUID exposed to guest
|
|
in the virtual BIOS. All choices except ``unique`` will change the serial when
|
|
migrating the instance to another host. Changing the choice of this option will
|
|
also affect existing instances on this host once they are stopped and started
|
|
again. It is recommended to use the default choice (``unique``) since that will
|
|
not change when an instance is migrated. However, if you have a need for
|
|
per-host serials in addition to per-instance serial numbers, then consider
|
|
restricting flavors via host aggregates.
|
|
"""
|
|
),
|
|
cfg.IntOpt('mem_stats_period_seconds',
|
|
default=10,
|
|
help='A number of seconds to memory usage statistics period. '
|
|
'Zero or negative value mean to disable memory usage '
|
|
'statistics.'),
|
|
cfg.ListOpt('uid_maps',
|
|
default=[],
|
|
help='List of uid targets and ranges.'
|
|
'Syntax is guest-uid:host-uid:count. '
|
|
'Maximum of 5 allowed.'),
|
|
cfg.ListOpt('gid_maps',
|
|
default=[],
|
|
help='List of guid targets and ranges.'
|
|
'Syntax is guest-gid:host-gid:count. '
|
|
'Maximum of 5 allowed.'),
|
|
cfg.IntOpt('realtime_scheduler_priority',
|
|
default=1,
|
|
help='In a realtime host context vCPUs for guest will run in '
|
|
'that scheduling priority. Priority depends on the host '
|
|
'kernel (usually 1-99)'),
|
|
cfg.ListOpt('enabled_perf_events',
|
|
default=[],
|
|
help= """
|
|
Performance events to monitor and collect statistics for.
|
|
|
|
This will allow you to specify a list of events to monitor low-level
|
|
performance of guests, and collect related statistics via the libvirt
|
|
driver, which in turn uses the Linux kernel's ``perf`` infrastructure.
|
|
With this config attribute set, Nova will generate libvirt guest XML to
|
|
monitor the specified events.
|
|
|
|
For example, to monitor the count of CPU cycles (total/elapsed) and the
|
|
count of cache misses, enable them as follows::
|
|
|
|
[libvirt]
|
|
enabled_perf_events = cpu_clock, cache_misses
|
|
|
|
Possible values: A string list. The list of supported events can be
|
|
found `here`__. Note that Intel CMT events - ``cmt``, ``mbmbt`` and
|
|
``mbml`` - are unsupported by recent Linux kernel versions (4.14+) and will be
|
|
ignored by nova.
|
|
|
|
__ https://libvirt.org/formatdomain.html#elementsPerf.
|
|
"""),
|
|
cfg.IntOpt('num_pcie_ports',
|
|
default=0,
|
|
min=0,
|
|
max=28,
|
|
help= """
|
|
The number of PCIe ports an instance will get.
|
|
|
|
Libvirt allows a custom number of PCIe ports (pcie-root-port controllers) a
|
|
target instance will get. Some will be used by default, rest will be available
|
|
for hotplug use.
|
|
|
|
By default we have just 1-2 free ports which limits hotplug.
|
|
|
|
More info: https://github.com/qemu/qemu/blob/master/docs/pcie.txt
|
|
|
|
Due to QEMU limitations for aarch64/virt maximum value is set to '28'.
|
|
|
|
Default value '0' moves calculating amount of ports to libvirt.
|
|
"""),
|
|
cfg.IntOpt('file_backed_memory',
|
|
default=0,
|
|
min=0,
|
|
help="""
|
|
Available capacity in MiB for file-backed memory.
|
|
|
|
Set to 0 to disable file-backed memory.
|
|
|
|
When enabled, instances will create memory files in the directory specified
|
|
in ``/etc/libvirt/qemu.conf``'s ``memory_backing_dir`` option. The default
|
|
location is ``/var/lib/libvirt/qemu/ram``.
|
|
|
|
When enabled, the value defined for this option is reported as the node memory
|
|
capacity. Compute node system memory will be used as a cache for file-backed
|
|
memory, via the kernel's pagecache mechanism.
|
|
|
|
.. note::
|
|
This feature is not compatible with hugepages.
|
|
|
|
.. note::
|
|
This feature is not compatible with memory overcommit.
|
|
|
|
Related options:
|
|
|
|
* ``virt_type`` must be set to ``kvm`` or ``qemu``.
|
|
* ``ram_allocation_ratio`` must be set to 1.0.
|
|
"""),
|
|
cfg.IntOpt('num_memory_encrypted_guests',
|
|
default=None,
|
|
min=0,
|
|
help="""
|
|
Maximum number of guests with encrypted memory which can run
|
|
concurrently on this compute host.
|
|
|
|
For now this is only relevant for AMD machines which support SEV
|
|
(Secure Encrypted Virtualization). Such machines have a limited
|
|
number of slots in their memory controller for storing encryption
|
|
keys. Each running guest with encrypted memory will consume one of
|
|
these slots.
|
|
|
|
The option may be reused for other equivalent technologies in the
|
|
future. If the machine does not support memory encryption, the option
|
|
will be ignored and inventory will be set to 0.
|
|
|
|
If the machine does support memory encryption, *for now* a value of
|
|
``None`` means an effectively unlimited inventory, i.e. no limit will
|
|
be imposed by Nova on the number of SEV guests which can be launched,
|
|
even though the underlying hardware will enforce its own limit.
|
|
However it is expected that in the future, auto-detection of the
|
|
inventory from the hardware will become possible, at which point
|
|
``None`` will cause auto-detection to automatically impose the correct
|
|
limit.
|
|
|
|
.. note::
|
|
|
|
It is recommended to read :ref:`the deployment documentation's
|
|
section on this option <num_memory_encrypted_guests>` before
|
|
deciding whether to configure this setting or leave it at the
|
|
default.
|
|
|
|
Related options:
|
|
|
|
* :oslo.config:option:`libvirt.virt_type` must be set to ``kvm``.
|
|
|
|
* It's recommended to consider including ``x86_64=q35`` in
|
|
:oslo.config:option:`libvirt.hw_machine_type`; see
|
|
:ref:`deploying-sev-capable-infrastructure` for more on this.
|
|
"""),
|
|
]
|
|
|
|
libvirt_imagebackend_opts = [
|
|
cfg.StrOpt('images_type',
|
|
default='default',
|
|
choices=('raw', 'flat', 'qcow2', 'lvm', 'rbd', 'ploop',
|
|
'default'),
|
|
help="""
|
|
VM Images format.
|
|
|
|
If default is specified, then use_cow_images flag is used instead of this
|
|
one.
|
|
|
|
Related options:
|
|
|
|
* compute.use_cow_images
|
|
* images_volume_group
|
|
* [workarounds]/ensure_libvirt_rbd_instance_dir_cleanup
|
|
* compute.force_raw_images
|
|
"""),
|
|
cfg.StrOpt('images_volume_group',
|
|
help="""
|
|
LVM Volume Group that is used for VM images, when you specify images_type=lvm
|
|
|
|
Related options:
|
|
|
|
* images_type
|
|
"""),
|
|
cfg.BoolOpt('sparse_logical_volumes',
|
|
default=False,
|
|
deprecated_for_removal=True,
|
|
deprecated_since='18.0.0',
|
|
deprecated_reason="""
|
|
Sparse logical volumes is a feature that is not tested hence not supported.
|
|
LVM logical volumes are preallocated by default. If you want thin provisioning,
|
|
use Cinder thin-provisioned volumes.
|
|
""",
|
|
help="""
|
|
Create sparse logical volumes (with virtualsize) if this flag is set to True.
|
|
"""),
|
|
cfg.StrOpt('images_rbd_pool',
|
|
default='rbd',
|
|
help='The RADOS pool in which rbd volumes are stored'),
|
|
cfg.StrOpt('images_rbd_ceph_conf',
|
|
default='', # default determined by librados
|
|
help='Path to the ceph configuration file to use'),
|
|
cfg.StrOpt('images_rbd_glance_store_name',
|
|
default='',
|
|
help="""
|
|
The name of the Glance store that represents the rbd cluster in use by
|
|
this node. If set, this will allow Nova to request that Glance copy an
|
|
image from an existing non-local store into the one named by this option
|
|
before booting so that proper Copy-on-Write behavior is maintained.
|
|
|
|
Related options:
|
|
|
|
* images_type - must be set to ``rbd``
|
|
* images_rbd_glance_copy_poll_interval - controls the status poll frequency
|
|
* images_rbd_glance_copy_timeout - controls the overall copy timeout
|
|
"""),
|
|
cfg.IntOpt('images_rbd_glance_copy_poll_interval',
|
|
default=15,
|
|
help="""
|
|
The interval in seconds with which to poll Glance after asking for it
|
|
to copy an image to the local rbd store. This affects how often we ask
|
|
Glance to report on copy completion, and thus should be short enough that
|
|
we notice quickly, but not too aggressive that we generate undue load on
|
|
the Glance server.
|
|
|
|
Related options:
|
|
|
|
* images_type - must be set to ``rbd``
|
|
* images_rbd_glance_store_name - must be set to a store name
|
|
"""),
|
|
cfg.IntOpt('images_rbd_glance_copy_timeout',
|
|
default=600,
|
|
help="""
|
|
The overall maximum time we will wait for Glance to complete an image
|
|
copy to our local rbd store. This should be long enough to allow large
|
|
images to be copied over the network link between our local store and the
|
|
one where images typically reside. The downside of setting this too long
|
|
is just to catch the case where the image copy is stalled or proceeding too
|
|
slowly to be useful. Actual errors will be reported by Glance and noticed
|
|
according to the poll interval.
|
|
|
|
Related options:
|
|
* images_type - must be set to ``rbd``
|
|
* images_rbd_glance_store_name - must be set to a store name
|
|
* images_rbd_glance_copy_poll_interval - controls the failure time-to-notice
|
|
"""),
|
|
cfg.StrOpt('hw_disk_discard',
|
|
choices=('ignore', 'unmap'),
|
|
help="""
|
|
Discard option for nova managed disks.
|
|
|
|
Requires:
|
|
|
|
* Libvirt >= 1.0.6
|
|
* Qemu >= 1.5 (raw format)
|
|
* Qemu >= 1.6 (qcow2 format)
|
|
"""),
|
|
]
|
|
|
|
libvirt_lvm_opts = [
|
|
cfg.StrOpt('volume_clear',
|
|
default='zero',
|
|
choices=[
|
|
('zero', 'Overwrite volumes with zeroes'),
|
|
('shred', 'Overwrite volumes repeatedly'),
|
|
('none', 'Do not wipe deleted volumes'),
|
|
],
|
|
help="""
|
|
Method used to wipe ephemeral disks when they are deleted. Only takes effect
|
|
if LVM is set as backing storage.
|
|
|
|
Related options:
|
|
|
|
* images_type - must be set to ``lvm``
|
|
* volume_clear_size
|
|
"""),
|
|
cfg.IntOpt('volume_clear_size',
|
|
default=0,
|
|
min=0,
|
|
help="""
|
|
Size of area in MiB, counting from the beginning of the allocated volume,
|
|
that will be cleared using method set in ``volume_clear`` option.
|
|
|
|
Possible values:
|
|
|
|
* 0 - clear whole volume
|
|
* >0 - clear specified amount of MiB
|
|
|
|
Related options:
|
|
|
|
* images_type - must be set to ``lvm``
|
|
* volume_clear - must be set and the value must be different than ``none``
|
|
for this option to have any impact
|
|
"""),
|
|
]
|
|
|
|
libvirt_utils_opts = [
|
|
cfg.BoolOpt('snapshot_compression',
|
|
default=False,
|
|
help="""
|
|
Enable snapshot compression for ``qcow2`` images.
|
|
|
|
Note: you can set ``snapshot_image_format`` to ``qcow2`` to force all
|
|
snapshots to be in ``qcow2`` format, independently from their original image
|
|
type.
|
|
|
|
Related options:
|
|
|
|
* snapshot_image_format
|
|
"""),
|
|
]
|
|
|
|
libvirt_vif_opts = [
|
|
cfg.BoolOpt('use_virtio_for_bridges',
|
|
default=True,
|
|
help='Use virtio for bridge interfaces with KVM/QEMU'),
|
|
]
|
|
|
|
libvirt_volume_opts = [
|
|
cfg.BoolOpt('volume_use_multipath',
|
|
default=False,
|
|
deprecated_name='iscsi_use_multipath',
|
|
help="""
|
|
Use multipath connection of the iSCSI or FC volume
|
|
|
|
Volumes can be connected in the LibVirt as multipath devices. This will
|
|
provide high availability and fault tolerance.
|
|
"""),
|
|
cfg.IntOpt('num_volume_scan_tries',
|
|
deprecated_name='num_iscsi_scan_tries',
|
|
default=5,
|
|
help="""
|
|
Number of times to scan given storage protocol to find volume.
|
|
"""),
|
|
]
|
|
|
|
libvirt_volume_aoe_opts = [
|
|
cfg.IntOpt('num_aoe_discover_tries',
|
|
default=3,
|
|
help="""
|
|
Number of times to rediscover AoE target to find volume.
|
|
|
|
Nova provides support for block storage attaching to hosts via AOE (ATA over
|
|
Ethernet). This option allows the user to specify the maximum number of retry
|
|
attempts that can be made to discover the AoE device.
|
|
""")
|
|
]
|
|
|
|
libvirt_volume_iscsi_opts = [
|
|
cfg.StrOpt('iscsi_iface',
|
|
deprecated_name='iscsi_transport',
|
|
help="""
|
|
The iSCSI transport iface to use to connect to target in case offload support
|
|
is desired.
|
|
|
|
Default format is of the form ``<transport_name>.<hwaddress>``, where
|
|
``<transport_name>`` is one of (``be2iscsi``, ``bnx2i``, ``cxgb3i``,
|
|
``cxgb4i``, ``qla4xxx``, ``ocs``, ``tcp``) and ``<hwaddress>`` is the MAC
|
|
address of the interface and can be generated via the ``iscsiadm -m iface``
|
|
command. Do not confuse the ``iscsi_iface`` parameter to be provided here with
|
|
the actual transport name.
|
|
""")
|
|
# iser is also supported, but use LibvirtISERVolumeDriver
|
|
# instead
|
|
]
|
|
|
|
libvirt_volume_iser_opts = [
|
|
cfg.IntOpt('num_iser_scan_tries',
|
|
default=5,
|
|
help="""
|
|
Number of times to scan iSER target to find volume.
|
|
|
|
iSER is a server network protocol that extends iSCSI protocol to use Remote
|
|
Direct Memory Access (RDMA). This option allows the user to specify the maximum
|
|
number of scan attempts that can be made to find iSER volume.
|
|
"""),
|
|
cfg.BoolOpt('iser_use_multipath',
|
|
default=False,
|
|
help="""
|
|
Use multipath connection of the iSER volume.
|
|
|
|
iSER volumes can be connected as multipath devices. This will provide high
|
|
availability and fault tolerance.
|
|
""")
|
|
]
|
|
|
|
libvirt_volume_net_opts = [
|
|
cfg.StrOpt('rbd_user',
|
|
help="""
|
|
The RADOS client name for accessing rbd(RADOS Block Devices) volumes.
|
|
|
|
Libvirt will refer to this user when connecting and authenticating with
|
|
the Ceph RBD server.
|
|
"""),
|
|
cfg.StrOpt('rbd_secret_uuid',
|
|
help="""
|
|
The libvirt UUID of the secret for the rbd_user volumes.
|
|
"""),
|
|
cfg.IntOpt('rbd_connect_timeout',
|
|
default=5,
|
|
help="""
|
|
The RADOS client timeout in seconds when initially connecting to the cluster.
|
|
"""),
|
|
cfg.IntOpt('rbd_destroy_volume_retry_interval',
|
|
default=5,
|
|
min=0,
|
|
help="""
|
|
Number of seconds to wait between each consecutive retry to destroy a
|
|
RBD volume.
|
|
|
|
Related options:
|
|
|
|
* [libvirt]/images_type = 'rbd'
|
|
"""),
|
|
cfg.IntOpt('rbd_destroy_volume_retries',
|
|
default=12,
|
|
min=0,
|
|
help="""
|
|
Number of retries to destroy a RBD volume.
|
|
|
|
Related options:
|
|
|
|
* [libvirt]/images_type = 'rbd'
|
|
"""),
|
|
]
|
|
|
|
libvirt_volume_nfs_opts = [
|
|
cfg.StrOpt('nfs_mount_point_base',
|
|
default=paths.state_path_def('mnt'),
|
|
help="""
|
|
Directory where the NFS volume is mounted on the compute node.
|
|
The default is 'mnt' directory of the location where nova's Python module
|
|
is installed.
|
|
|
|
NFS provides shared storage for the OpenStack Block Storage service.
|
|
|
|
Possible values:
|
|
|
|
* A string representing absolute path of mount point.
|
|
"""),
|
|
cfg.StrOpt('nfs_mount_options',
|
|
help="""
|
|
Mount options passed to the NFS client. See section of the nfs man page
|
|
for details.
|
|
|
|
Mount options controls the way the filesystem is mounted and how the
|
|
NFS client behaves when accessing files on this mount point.
|
|
|
|
Possible values:
|
|
|
|
* Any string representing mount options separated by commas.
|
|
* Example string: vers=3,lookupcache=pos
|
|
"""),
|
|
]
|
|
|
|
libvirt_volume_quobyte_opts = [
|
|
cfg.StrOpt('quobyte_mount_point_base',
|
|
default=paths.state_path_def('mnt'),
|
|
help="""
|
|
Directory where the Quobyte volume is mounted on the compute node.
|
|
|
|
Nova supports Quobyte volume driver that enables storing Block Storage
|
|
service volumes on a Quobyte storage back end. This Option specifies the
|
|
path of the directory where Quobyte volume is mounted.
|
|
|
|
Possible values:
|
|
|
|
* A string representing absolute path of mount point.
|
|
"""),
|
|
cfg.StrOpt('quobyte_client_cfg',
|
|
help='Path to a Quobyte Client configuration file.'),
|
|
]
|
|
|
|
libvirt_volume_smbfs_opts = [
|
|
cfg.StrOpt('smbfs_mount_point_base',
|
|
default=paths.state_path_def('mnt'),
|
|
help="""
|
|
Directory where the SMBFS shares are mounted on the compute node.
|
|
"""),
|
|
cfg.StrOpt('smbfs_mount_options',
|
|
default='',
|
|
help="""
|
|
Mount options passed to the SMBFS client.
|
|
|
|
Provide SMBFS options as a single string containing all parameters.
|
|
See mount.cifs man page for details. Note that the libvirt-qemu ``uid``
|
|
and ``gid`` must be specified.
|
|
"""),
|
|
]
|
|
|
|
libvirt_remotefs_opts = [
|
|
cfg.StrOpt('remote_filesystem_transport',
|
|
default='ssh',
|
|
choices=('ssh', 'rsync'),
|
|
help="""
|
|
libvirt's transport method for remote file operations.
|
|
|
|
Because libvirt cannot use RPC to copy files over network to/from other
|
|
compute nodes, other method must be used for:
|
|
|
|
* creating directory on remote host
|
|
* creating file on remote host
|
|
* removing file from remote host
|
|
* copying file to remote host
|
|
""")
|
|
]
|
|
|
|
libvirt_volume_vzstorage_opts = [
|
|
cfg.StrOpt('vzstorage_mount_point_base',
|
|
default=paths.state_path_def('mnt'),
|
|
help="""
|
|
Directory where the Virtuozzo Storage clusters are mounted on the compute
|
|
node.
|
|
|
|
This option defines non-standard mountpoint for Vzstorage cluster.
|
|
|
|
Related options:
|
|
|
|
* vzstorage_mount_* group of parameters
|
|
"""
|
|
),
|
|
cfg.StrOpt('vzstorage_mount_user',
|
|
default='stack',
|
|
help="""
|
|
Mount owner user name.
|
|
|
|
This option defines the owner user of Vzstorage cluster mountpoint.
|
|
|
|
Related options:
|
|
|
|
* vzstorage_mount_* group of parameters
|
|
"""
|
|
),
|
|
cfg.StrOpt('vzstorage_mount_group',
|
|
default='qemu',
|
|
help="""
|
|
Mount owner group name.
|
|
|
|
This option defines the owner group of Vzstorage cluster mountpoint.
|
|
|
|
Related options:
|
|
|
|
* vzstorage_mount_* group of parameters
|
|
"""
|
|
),
|
|
cfg.StrOpt('vzstorage_mount_perms',
|
|
default='0770',
|
|
help="""
|
|
Mount access mode.
|
|
|
|
This option defines the access bits of Vzstorage cluster mountpoint,
|
|
in the format similar to one of chmod(1) utility, like this: 0770.
|
|
It consists of one to four digits ranging from 0 to 7, with missing
|
|
lead digits assumed to be 0's.
|
|
|
|
Related options:
|
|
|
|
* vzstorage_mount_* group of parameters
|
|
"""
|
|
),
|
|
cfg.StrOpt('vzstorage_log_path',
|
|
default='/var/log/vstorage/%(cluster_name)s/nova.log.gz',
|
|
help="""
|
|
Path to vzstorage client log.
|
|
|
|
This option defines the log of cluster operations,
|
|
it should include "%(cluster_name)s" template to separate
|
|
logs from multiple shares.
|
|
|
|
Related options:
|
|
|
|
* vzstorage_mount_opts may include more detailed logging options.
|
|
"""
|
|
),
|
|
cfg.StrOpt('vzstorage_cache_path',
|
|
default=None,
|
|
help="""
|
|
Path to the SSD cache file.
|
|
|
|
You can attach an SSD drive to a client and configure the drive to store
|
|
a local cache of frequently accessed data. By having a local cache on a
|
|
client's SSD drive, you can increase the overall cluster performance by
|
|
up to 10 and more times.
|
|
WARNING! There is a lot of SSD models which are not server grade and
|
|
may loose arbitrary set of data changes on power loss.
|
|
Such SSDs should not be used in Vstorage and are dangerous as may lead
|
|
to data corruptions and inconsistencies. Please consult with the manual
|
|
on which SSD models are known to be safe or verify it using
|
|
vstorage-hwflush-check(1) utility.
|
|
|
|
This option defines the path which should include "%(cluster_name)s"
|
|
template to separate caches from multiple shares.
|
|
|
|
Related options:
|
|
|
|
* vzstorage_mount_opts may include more detailed cache options.
|
|
"""
|
|
),
|
|
cfg.ListOpt('vzstorage_mount_opts',
|
|
default=[],
|
|
help="""
|
|
Extra mount options for pstorage-mount
|
|
|
|
For full description of them, see
|
|
https://static.openvz.org/vz-man/man1/pstorage-mount.1.gz.html
|
|
Format is a python string representation of arguments list, like:
|
|
"[\'-v\', \'-R\', \'500\']"
|
|
Shouldn\'t include -c, -l, -C, -u, -g and -m as those have
|
|
explicit vzstorage_* options.
|
|
|
|
Related options:
|
|
|
|
* All other vzstorage_* options
|
|
"""
|
|
),
|
|
]
|
|
|
|
|
|
# The queue size requires value to be a power of two from [256, 1024]
|
|
# range.
|
|
# https://libvirt.org/formatdomain.html#elementsDriverBackendOptions
|
|
QueueSizeType = types.Integer(choices=(256, 512, 1024))
|
|
|
|
libvirt_virtio_queue_sizes = [
|
|
cfg.Opt('rx_queue_size',
|
|
type=QueueSizeType,
|
|
help="""
|
|
Configure virtio rx queue size.
|
|
|
|
This option is only usable for virtio-net device with vhost and
|
|
vhost-user backend. Available only with QEMU/KVM. Requires libvirt
|
|
v2.3 QEMU v2.7."""),
|
|
cfg.Opt('tx_queue_size',
|
|
type=QueueSizeType,
|
|
help="""
|
|
Configure virtio tx queue size.
|
|
|
|
This option is only usable for virtio-net device with vhost-user
|
|
backend. Available only with QEMU/KVM. Requires libvirt v3.7 QEMU
|
|
v2.10."""),
|
|
cfg.IntOpt('max_queues', default=None, min=1, help="""
|
|
The maximum number of virtio queue pairs that can be enabled
|
|
when creating a multiqueue guest. The number of virtio queues
|
|
allocated will be the lesser of the CPUs requested by the guest
|
|
and the max value defined. By default, this value is set to none
|
|
meaning the legacy limits based on the reported kernel
|
|
major version will be used.
|
|
"""),
|
|
|
|
]
|
|
|
|
|
|
libvirt_volume_nvmeof_opts = [
|
|
cfg.IntOpt('num_nvme_discover_tries',
|
|
default=5,
|
|
help="""
|
|
Number of times to rediscover NVMe target to find volume
|
|
|
|
Nova provides support for block storage attaching to hosts via NVMe
|
|
(Non-Volatile Memory Express). This option allows the user to specify the
|
|
maximum number of retry attempts that can be made to discover the NVMe device.
|
|
"""),
|
|
]
|
|
|
|
|
|
libvirt_pmem_opts = [
|
|
cfg.ListOpt('pmem_namespaces',
|
|
item_type=cfg.types.String(),
|
|
default=[],
|
|
help="""
|
|
Configure persistent memory(pmem) namespaces.
|
|
|
|
These namespaces must have been already created on the host. This config
|
|
option is in the following format::
|
|
|
|
"$LABEL:$NSNAME[|$NSNAME][,$LABEL:$NSNAME[|$NSNAME]]"
|
|
|
|
* ``$NSNAME`` is the name of the pmem namespace.
|
|
* ``$LABEL`` represents one resource class, this is used to generate
|
|
the resource class name as ``CUSTOM_PMEM_NAMESPACE_$LABEL``.
|
|
|
|
For example::
|
|
|
|
[libvirt]
|
|
pmem_namespaces=128G:ns0|ns1|ns2|ns3,262144MB:ns4|ns5,MEDIUM:ns6|ns7
|
|
|
|
"""),
|
|
]
|
|
|
|
|
|
libvirt_vtpm_opts = [
|
|
cfg.BoolOpt('swtpm_enabled',
|
|
default=False,
|
|
help="""
|
|
Enable emulated TPM (Trusted Platform Module) in guests.
|
|
"""),
|
|
cfg.StrOpt('swtpm_user',
|
|
default='tss',
|
|
help="""
|
|
User that swtpm binary runs as.
|
|
|
|
When using emulated TPM, the ``swtpm`` binary will run to emulate a TPM
|
|
device. The user this binary runs as depends on libvirt configuration, with
|
|
``tss`` being the default.
|
|
|
|
In order to support cold migration and resize, nova needs to know what user
|
|
the swtpm binary is running as in order to ensure that files get the proper
|
|
ownership after being moved between nodes.
|
|
|
|
Related options:
|
|
|
|
* ``swtpm_group`` must also be set.
|
|
"""),
|
|
cfg.StrOpt('swtpm_group',
|
|
default='tss',
|
|
help="""
|
|
Group that swtpm binary runs as.
|
|
|
|
When using emulated TPM, the ``swtpm`` binary will run to emulate a TPM
|
|
device. The user this binary runs as depends on libvirt configuration, with
|
|
``tss`` being the default.
|
|
|
|
In order to support cold migration and resize, nova needs to know what group
|
|
the swtpm binary is running as in order to ensure that files get the proper
|
|
ownership after being moved between nodes.
|
|
|
|
Related options:
|
|
|
|
* ``swtpm_user`` must also be set.
|
|
"""),
|
|
]
|
|
|
|
|
|
ALL_OPTS = list(itertools.chain(
|
|
libvirt_general_opts,
|
|
libvirt_imagebackend_opts,
|
|
libvirt_lvm_opts,
|
|
libvirt_utils_opts,
|
|
libvirt_vif_opts,
|
|
libvirt_volume_opts,
|
|
libvirt_volume_aoe_opts,
|
|
libvirt_volume_iscsi_opts,
|
|
libvirt_volume_iser_opts,
|
|
libvirt_volume_net_opts,
|
|
libvirt_volume_nfs_opts,
|
|
libvirt_volume_quobyte_opts,
|
|
libvirt_volume_smbfs_opts,
|
|
libvirt_remotefs_opts,
|
|
libvirt_volume_vzstorage_opts,
|
|
libvirt_virtio_queue_sizes,
|
|
libvirt_volume_nvmeof_opts,
|
|
libvirt_pmem_opts,
|
|
libvirt_vtpm_opts,
|
|
))
|
|
|
|
|
|
def register_opts(conf):
|
|
conf.register_group(libvirt_group)
|
|
conf.register_opts(ALL_OPTS, group=libvirt_group)
|
|
|
|
|
|
def list_opts():
|
|