
something changed and expected logs are in stdout rather than stderr even though it does makes sense as stdout. i have no idea why it was writing to stderr earlier when it shouldn't have. Related-Bug: #1635042 Change-Id: I9feed1a5050a4d99cb1c0130c13e86ceeda47563
174 lines
7.1 KiB
Python
174 lines
7.1 KiB
Python
# Copyright 2012 eNovance <licensing@enovance.com>
|
|
#
|
|
# Licensed under the Apache License, Version 2.0 (the "License"); you may
|
|
# not use this file except in compliance with the License. You may obtain
|
|
# a copy of the License at
|
|
#
|
|
# http://www.apache.org/licenses/LICENSE-2.0
|
|
#
|
|
# Unless required by applicable law or agreed to in writing, software
|
|
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
|
|
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
|
|
# License for the specific language governing permissions and limitations
|
|
# under the License.
|
|
|
|
import os
|
|
import subprocess
|
|
import time
|
|
|
|
from oslo_utils import fileutils
|
|
import six
|
|
|
|
from ceilometer.tests import base
|
|
|
|
|
|
class BinTestCase(base.BaseTestCase):
|
|
def setUp(self):
|
|
super(BinTestCase, self).setUp()
|
|
content = ("[DEFAULT]\n"
|
|
"transport_url = fake://\n"
|
|
"[database]\n"
|
|
"connection=log://localhost\n")
|
|
if six.PY3:
|
|
content = content.encode('utf-8')
|
|
self.tempfile = fileutils.write_to_tempfile(content=content,
|
|
prefix='ceilometer',
|
|
suffix='.conf')
|
|
|
|
def tearDown(self):
|
|
super(BinTestCase, self).tearDown()
|
|
os.remove(self.tempfile)
|
|
|
|
def test_dbsync_run(self):
|
|
subp = subprocess.Popen(['ceilometer-dbsync',
|
|
"--config-file=%s" % self.tempfile])
|
|
self.assertEqual(0, subp.wait())
|
|
|
|
def test_run_expirer_ttl_disabled(self):
|
|
subp = subprocess.Popen(['ceilometer-expirer',
|
|
'-d',
|
|
"--config-file=%s" % self.tempfile],
|
|
stdout=subprocess.PIPE)
|
|
stdout, __ = subp.communicate()
|
|
self.assertEqual(0, subp.poll())
|
|
self.assertIn(b"Nothing to clean, database metering "
|
|
b"time to live is disabled", stdout)
|
|
self.assertIn(b"Nothing to clean, database event "
|
|
b"time to live is disabled", stdout)
|
|
|
|
def _test_run_expirer_ttl_enabled(self, ttl_name, data_name):
|
|
content = ("[DEFAULT]\n"
|
|
"transport_url = fake://\n"
|
|
"[database]\n"
|
|
"%s=1\n"
|
|
"connection=log://localhost\n" % ttl_name)
|
|
if six.PY3:
|
|
content = content.encode('utf-8')
|
|
self.tempfile = fileutils.write_to_tempfile(content=content,
|
|
prefix='ceilometer',
|
|
suffix='.conf')
|
|
subp = subprocess.Popen(['ceilometer-expirer',
|
|
'-d',
|
|
"--config-file=%s" % self.tempfile],
|
|
stdout=subprocess.PIPE)
|
|
stdout, __ = subp.communicate()
|
|
self.assertEqual(0, subp.poll())
|
|
msg = "Dropping %s data with TTL 1" % data_name
|
|
if six.PY3:
|
|
msg = msg.encode('utf-8')
|
|
self.assertIn(msg, stdout)
|
|
|
|
def test_run_expirer_ttl_enabled(self):
|
|
self._test_run_expirer_ttl_enabled('metering_time_to_live',
|
|
'metering')
|
|
self._test_run_expirer_ttl_enabled('time_to_live', 'metering')
|
|
self._test_run_expirer_ttl_enabled('event_time_to_live', 'event')
|
|
|
|
|
|
class BinSendSampleTestCase(base.BaseTestCase):
|
|
def setUp(self):
|
|
super(BinSendSampleTestCase, self).setUp()
|
|
pipeline_cfg_file = self.path_get('etc/ceilometer/pipeline.yaml')
|
|
content = ("[DEFAULT]\n"
|
|
"transport_url = fake://\n"
|
|
"pipeline_cfg_file={0}\n".format(pipeline_cfg_file))
|
|
if six.PY3:
|
|
content = content.encode('utf-8')
|
|
|
|
self.tempfile = fileutils.write_to_tempfile(content=content,
|
|
prefix='ceilometer',
|
|
suffix='.conf')
|
|
|
|
def tearDown(self):
|
|
super(BinSendSampleTestCase, self).tearDown()
|
|
os.remove(self.tempfile)
|
|
|
|
def test_send_counter_run(self):
|
|
subp = subprocess.Popen(['ceilometer-send-sample',
|
|
"--config-file=%s" % self.tempfile,
|
|
"--sample-resource=someuuid",
|
|
"--sample-name=mycounter"])
|
|
self.assertEqual(0, subp.wait())
|
|
|
|
|
|
class BinCeilometerPollingServiceTestCase(base.BaseTestCase):
|
|
def setUp(self):
|
|
super(BinCeilometerPollingServiceTestCase, self).setUp()
|
|
self.tempfile = None
|
|
self.subp = None
|
|
|
|
def tearDown(self):
|
|
if self.subp:
|
|
try:
|
|
self.subp.kill()
|
|
except OSError:
|
|
pass
|
|
os.remove(self.tempfile)
|
|
super(BinCeilometerPollingServiceTestCase, self).tearDown()
|
|
|
|
def test_starting_with_duplication_namespaces(self):
|
|
content = ("[DEFAULT]\n"
|
|
"transport_url = fake://\n"
|
|
"[database]\n"
|
|
"connection=log://localhost\n")
|
|
if six.PY3:
|
|
content = content.encode('utf-8')
|
|
self.tempfile = fileutils.write_to_tempfile(content=content,
|
|
prefix='ceilometer',
|
|
suffix='.conf')
|
|
self.subp = subprocess.Popen(['ceilometer-polling',
|
|
"--config-file=%s" % self.tempfile,
|
|
"--polling-namespaces",
|
|
"compute",
|
|
"compute"],
|
|
stderr=subprocess.PIPE)
|
|
expected = (b'Duplicated values: [\'compute\', \'compute\'] '
|
|
b'found in CLI options, auto de-duplicated')
|
|
# NOTE(gordc): polling process won't quit so wait for a bit and check
|
|
start = time.time()
|
|
while time.time() - start < 5:
|
|
output = self.subp.stderr.readline()
|
|
if expected in output:
|
|
break
|
|
else:
|
|
self.fail('Did not detect expected warning: %s' % expected)
|
|
|
|
def test_polling_namespaces_invalid_value_in_config(self):
|
|
content = ("[DEFAULT]\n"
|
|
"transport_url = fake://\n"
|
|
"polling_namespaces = ['central']\n"
|
|
"[database]\n"
|
|
"connection=log://localhost\n")
|
|
if six.PY3:
|
|
content = content.encode('utf-8')
|
|
self.tempfile = fileutils.write_to_tempfile(content=content,
|
|
prefix='ceilometer',
|
|
suffix='.conf')
|
|
self.subp = subprocess.Popen(
|
|
["ceilometer-polling", "--config-file=%s" % self.tempfile],
|
|
stderr=subprocess.PIPE)
|
|
__, err = self.subp.communicate()
|
|
expected = ("Exception: Valid values are ['compute', 'central', "
|
|
"'ipmi'], but found [\"['central']\"]")
|
|
self.assertIn(expected, err)
|