Do collector setup and storage cleanup for all backends
It appears that a bit of overzealous copy and pasting of commands has meant that: * the number of collectors was not being set for mongodb, which may be a cause of performance issues in the gate * the cleanup was not being called for the sql backend, which leaves behind wsgi config files when that backend is chosen Change-Id: I013f14f8b167e564f794333c0fe5c8f421bb25a9
This commit is contained in:
parent
27822d05c9
commit
cac2b26d06
@ -213,23 +213,20 @@ function _ceilometer_configure_storage_backend {
|
||||
iniset $CEILOMETER_CONF database alarm_connection $(database_connection_url ceilometer)
|
||||
iniset $CEILOMETER_CONF database event_connection $(database_connection_url ceilometer)
|
||||
iniset $CEILOMETER_CONF database metering_connection $(database_connection_url ceilometer)
|
||||
iniset $CEILOMETER_CONF collector workers $API_WORKERS
|
||||
elif [ "$CEILOMETER_BACKEND" = 'es' ] ; then
|
||||
# es is only supported for events. we will use sql for alarming/metering.
|
||||
iniset $CEILOMETER_CONF database alarm_connection $(database_connection_url ceilometer)
|
||||
iniset $CEILOMETER_CONF database event_connection es://localhost:9200
|
||||
iniset $CEILOMETER_CONF database metering_connection $(database_connection_url ceilometer)
|
||||
iniset $CEILOMETER_CONF collector workers $API_WORKERS
|
||||
${TOP_DIR}/pkg/elasticsearch.sh start
|
||||
cleanup_ceilometer
|
||||
elif [ "$CEILOMETER_BACKEND" = 'mongodb' ] ; then
|
||||
iniset $CEILOMETER_CONF database alarm_connection mongodb://localhost:27017/ceilometer
|
||||
iniset $CEILOMETER_CONF database event_connection mongodb://localhost:27017/ceilometer
|
||||
iniset $CEILOMETER_CONF database metering_connection mongodb://localhost:27017/ceilometer
|
||||
cleanup_ceilometer
|
||||
else
|
||||
die $LINENO "Unable to configure unknown CEILOMETER_BACKEND $CEILOMETER_BACKEND"
|
||||
fi
|
||||
cleanup_ceilometer
|
||||
}
|
||||
|
||||
# Configure Ceilometer
|
||||
@ -285,6 +282,7 @@ function configure_ceilometer {
|
||||
|
||||
# Configure storage
|
||||
_ceilometer_configure_storage_backend
|
||||
iniset $CEILOMETER_CONF collector workers $API_WORKERS
|
||||
|
||||
if [[ "$VIRT_DRIVER" = 'vsphere' ]]; then
|
||||
iniset $CEILOMETER_CONF DEFAULT hypervisor_inspector vsphere
|
||||
|
Loading…